Technical data

17
OVERLOAD
U
OUT
LOW
U
OUT
OK
+12V OK
CHARGE
U
PRI
FAIL
OVERLOAD
U
OUT
LOW
U
OUT
OK
+12V OK
CHARGE
U
PRI
FAIL
OVERLOAD
U
OUT
LOW
U
OUT
OK
+12V OK
CHARGE
U
PRI
FAIL
OVERLOAD
U
OUT
LOW
U
OUT
OK
+12V OK
CHARGE
U
PRI
FAIL
OVERLOAD
U
OUT
LOW
U
OUT
OK
+12V OK
CHARGE
U
PRI
FAIL
OVERLOAD
U
OUT
LOW
U
OUT
OK
+12V OK
CHARGE
U
PRI
FAIL
OVERLOAD
U
OUT
LOW
U
OUT
OK
+12V OK
CHARGE
U
PRI
FAIL
85 - 253 V AC/ 50 - 60 Hz
max. 13 VA/ 2 W
max. 180 VA/ 111 W
- safety fuse T3.15 A inside the unit
- electronic protection (short circuit
current and thermal overload)
- DC 24V (two 12V batteries in series)
-safety fuse F6.3 A inside the unit
- electronic protection against current overload
- each battery separately
- separately routed extreme terminals (24)
- for the battery voltage <21 V
- when exceeding discharge current 4.2 A
27.6 V
3.6 A
12.2 V
0.35 A
about 88%
up to 1 s
adjustable from 0.2 to 2.2 A
green LED U
OUT
OK
ashing red LED U
PRI
FAIL
yellow LED U
OUT
LOW
green LED + 12 V OK
red LED OVERLOAD
yellow LED CHARGE
closed, when power supply works (not blinking LED U
PRI
FAIL)
closed, if U
OUT
> 21V (not lit red LED OVERLOAD)
open collector current limited
50 V DC
50 mA
at 10 mA ... 140 mV
at 30 mA ... 400 mV
at 50 mA ... 700 mV
4 kV
row
max. 1 x 2.5, max. 2 x 1.5 (with sleeve max. 1 x 1.5)
-20 °C to +55 °C
-30 °C to +70 °C
20 to 90 % RH
IP40 front panel, IP20 terminals
III.
2
arbitrary, vertical is optimum
on the DIN rail EN60715
6-MODULE
90 x 105 x 65 mm
392 g
General: EN61204
Safety: EN61204-7
EMC: EN61204-3
Power supply:
Power load (
apparent / active):
Power consumption at max. load (apparent / active):
Protection:
Power supply:
Protection:
Terminals for connecting the battery:
Automatic disconnect the battery:
Output voltage 1:
Max. capacity:
Output voltage 2:
Max. capacity:
The overall effi ciency of resources:
Time delay after connecting to the AC network:
Max. charging current:
Output voltage 27 V OK (U
OUT
> 24 V):
Switch. power supply does not work (does not oscillate):
Low output voltage (21 V < U
OUT
< 24V):
Output voltage 12 V OK (U > 11 V):
Overloading the power supply (U
OUT
< 21 V):
Charging the battery (charging current > 50mA):
STATUS output 1 (U
PRI
OK):
STATUS output 2 (U
OUT
OK):
Output type:
Max. connectable voltage:
Max. current output:
Voltage drop on the switch max:
Electric strength AC input - output:
The connection terminals:
Cable size (mm2):
Operating temperature:
Storage Temperature:
Working humidity:
Cover:
Overvoltage category:
Degree of pollution:
Working position:
Installation:
Execution:
Dimensions:
Weight:
Related standards:
TECHNICAL PARAMETERS
OTHER DATA
OUTPUT STATUS
LED SIGNALIZATION
AC INPUT
DC INPUT
OUTPUTS
switching power supply works correctly
output voltage 27V is correct (U
OUT
>24V)
output voltage 12V is correct
batteries are recharged
switching power supply works correctly
low output voltage 27V (21V<U
OUT
<24V)
output voltage 12V is correct
batteries are not recharged
switching power supply is overload
low output voltage 27V (U
OUT
<21V)
low output voltage 12V
batteries are not recharged
switching power supply works correctly
output voltage 27V is correct (U
OUT
>24V)
low output voltage 12V (short-circuit, overload)
batteries are recharged
switching power supply works correctly
output voltage 27V is correct (U
OUT
>24V)
output voltage 12V is correct
power supply is overload
batteries are not recharged
switching power supply not working correctly -
UPS mode
output voltage 27V is correct (U
OUT
>24V)
output voltage 12V is correct
batteries are not recharged
switching power supply not working correctly -
UPS mode
low output voltage 27V (21V<U
OUT
<24V)
output voltage 12V is correct
batteries are not recharged
Indication LED