Technical data

27
JA3-02B/DC 8595188132718
M
JA3-02B/DC
+
-
CIB
CIB
JA3-02B/DC actuator serves to control blinds, shutters, garage doors, entrance gates, etc.
Operates electrical motors, which are controlled in 2 directions and have a built-in
limit switch.
JA3-02B/DC controlled electric drives with supply voltages up to 24 V DC, where the
direction of rotation of the driver is controlled by changing the voltage polarity of the
motor.
The unit is equipped with thermal and overcurrent overload protection outputs.
Status of units is indicated by green LED RUN on the front panel:
- with the supply voltage connected (through CIB) and the unit is not controlled by bus
CIB, LED RUN shines.
- with the supply voltage connected (through CIB) and the unit is controlled by bus CIB,
LED RUN fl ashes.
Status of output contacts UP/DOWN (
):
- while contact UP (
) is switched, red LED shines (orange).
- while contact DOWN (
) is switched, green LED shines.
Input for thermo sensor TC/TZ (more information about sensors - see accessories).
JA3-02B/DC is designed for mounting into an installation box.
EAN code
OUTPUTS
POWER SUPPLY
CONNECTION
OPERATING CONDITIONS
DIMENSIONS AND WEIGHT
INPUT
COMMUNICATION
input for external thermo sensor
TC, TZ; see accessories
-20 to +100°C / 0.5°C from the range
3.75 kV, SELV by EN 60950
0.85A*
1.5 A / < 3s
12 - 24 V DC
red (orange) LED
green LED
CIB
27 V DC/60mA, from CIB BUS
green LED RUN
terminal 0.5 - 1 mm
2
4 x conductor CY
0.75 mm
2
-20 to+50°C
-30 to+70°C
IP30
operative control device
individual control device
1.B.E
FR-0
class 2
2.5 kV
II.
2
any
into an installation box
49 x 49 x 13 mm
32 g
Thermo input for temperature
measuring:
Range and accuracy of thermomeasuring:
Insulative voltage between outputs
and internal circuits:
Rated current:
Peak current:
Switched voltage:
Output indication UP, (
) :
Output indication DOWN, (
) :
Installation BUS:
Supply voltage/rated current:
Status indication unit:
Data terminals:
Power outputs:
Operating temperature:
Storage temperature:
Protection degree:
Control device purpose:
Control device construction:
Characteristics of automatic operation:
Heat and fi re resistance category:
Anti-shock category (immunity):
Rated impulse voltage:
Overvoltage category:
Pollution degree:
Operation position:
Installation:
Dimensions:
Weight:
TECHNICAL PARAMETERS
Example of connection
supply voltage
motors
* Maximal operation time of outputs with rated current 0.85A is 10 minutes…after
that the output heating protection activates. The lower the current, the longer
duration of protection.
Shutter actuator JA3-02B/DC
temperature sensor TC/TZ