Use and Care Manual

Installation of electrical components must be done by a licensed electrician.
Important: All units need a NEMA plug to be plugged into a GFCI outlet that is connected
to a separate circuit with a 20AMP breaker run directly from breaker panel box.
***WARNING*** If the GFCI fails to operate, there is ground current owing, indicating the
possibility of electrical shock. Do not use your Walk In Tub until a repairman has addressed
the fault.
Before making any electrical connections, make certain that the electrical connection is
turned OFF at the breaker. Take precaution so as the breaker is not switched accidentally
during the installation process.
All units with plug in motors and or heaters must be connected to a (GFCI)
Ground Fault Circuit Interrupter. This should be tested on a regular basis.
To test the GFCI, push the test button. Upon testing, the GFCI should interrupt the power.
Push the reset button to restore power.
Electrical Installation Requirements