After both the electrical and plumbing installation are done, a nal inspection of these parts
needs to be completed before nishing the installation.
Close the drain and ll the Walk In Tub until it is up to a normal water height level which is 1"
to 2" below the overow and drain lever.
Allow the water to stand in Walk In Tub for 30 minutes and then inspect all plumbing and
seals for leaks. If there are any leaks or concerns call 1-800-480-6850.
If the Walk In Tub is jetted, supply electricity to unit and run for 10 minutes then inspect for
leaks. Inspect the unions around the pump; if leaks persist from the unions after tightening;
loosen the unions and insure that the 0-ring is seated properly.
If the pumps do not operate check the breaker to insure power is on and the cable
connection the controls to the pump is attached.
Ensure all jets are opening and working. Make sure they operate at all speeds.
Before lling your Ella Walk In Tub with water, be sure to wipe down the door seal and
the surrounding surface of the door jam. Use a damp washcloth to remove any debris,
construction dust and oils that may prevent the seal from working properly.
Fill your Ella Walk In Tub with water. After at least 5 minutes check the installation for leaks
along the door seam and plumbing connections.
If applicable, turn on the pump and or blower, let it run for at least 5 minutes. Check again
for leaks while the equipment is still running. Check by hand where visual inspections are not
possible.
Final Inspections
www.ellasbubbles.com Page 15 07/14
CLOSED
OPEN
Overow and Drain Lever