Product Electric Range Specification Sheet

C
OMBINATION
RANGES
A
LL GAS
RANGES
E
LECTRIC
WALL
OVENS
E
LECTRIC
RANGES
U
PPER CABINET
POWER RATING
OVENS
RANGE DIMENSIONS
Four Burner Model: 30 1/8" W x 67 7/8" H x 29 1/2" D. Six Burner
Model: 44 1/4" W x 67 7/8" H x 29 1/2" D. Our 30" models will fit into a
30 1/4" opening without cabinet alterations. Short leg models require a
minimum opening of 30 3/4", and are 65 7/8" high.
R
ANGETOPS
RANGES
FEATURES & SPECIFICATIONS
1850 1855 1865 1870 1875 1860 1867 1880
Range Widths *30 1⁄8" 44 1⁄4" 44 1⁄4" *30 1⁄8" 44 1⁄4" *30 1⁄8" 44 1⁄4" 29 7⁄8"
Self-Cleaning Electric Oven (4.3 cu. ft.) •••••
Oven Size: 25" W x 16" H x 18 3⁄4" D
Electric Self-Cleaning Convection Oven (4.0 cu. ft.) optional optional optional optional optional
Oven Size: 25" W x 16" H x 16 5⁄18" D standard on STE Models
Gas Self-Cleaning Oven with waist high Broiler (4.0 cu. ft.) ••
Oven Size: 25" W x 16" H x 18" D
“Stay Hot Food Warmer •••
Electronic Oven Control ••••••••
Delayed Start Baking ••••••••
Dual Element Baking •••••
Vari. Temp. Broil ••••••••
Door Activated Oven Light ••••••••
Heavy Duty, Plated Oven Racks ••••••••
Porcelain Enamel Broiler Pan ••••••••
Electric High–speed Radiant Elements under glass (ST) optional optional
High–Speed Radiant Elements
under glass with Electronic Control (STE) optional optional
Gas: Sealed Surface Burners with cast grates 4••••
Converts to L.P. (Propane) •••••
Gas Top Burners, 8,000* BTU 22323
Gas Top Burners, 12,000* BTU 11212
Superburner, 15,000* BTU 11111
*Ratings for liquid propane are approximately 10% lower
Ultra Temp Electric Cast Elements optional optional
Electric High Speed Radiant Elements under glass optional
Porcelain Enamel Work Surface (replaces two burners/elements) optional optional
Electronic Spark with Re–ignition •••••
Easy Clean Porcelain Top or Top Frame •••••••
Nickel Trimmed Range Top •••••••
350 CFM Exhaust Fan standard (recirclating and outside vent) •••••••
636 CFM In-line Exhaust blower (outside vent only) optional optional optional optional optional optional optional
Cooking Surface Light, Night Light •••••••
“Feather Touch Tempered Glass Oven Control Panel •••••••
Power Source (208 to 250V) appliance rating 220V-35A 220V-50A 220V-30A 220V-20A 220V-20A 120V-5A 120V-6A 220V-30A
Power Ratings NG (BTUs) 43,000 43,000 63,000 58,000 78,000
Power Ratings LP (BTUs) 38,700 38,700 56,700 52,200 70,200
Power ratings/oven burner NG (BTUs) 16,000 16,000
Shipping Weight 375 lbs. 410 lbs. 420 lbs. 385 lbs. 425 lbs. 395 lbs. 435 lbs. 200 lbs.
NATURAL GAS OR PROPANE?
Ranges are built to accommodate natural gas unless propane (LP) has been specified on your order. Conversion parts are availableand are easyto install. (See product manual for instructions.)
IMPORTANT
Fitting Range into CabinetOpening: Four Burner Models: If you aredesigning
cabinets to fitrange, leave 33" between base cabinets. Countertopover-
hangs on each side should be 1-3/8".Ranges will fit openings as small as
30-1/4".Shortleg models require 31" minimumclearance between counter-
tops. SixBurner Models:Require45-1/2"opening between basecabinets.
Leftcountertop overhang should be 1-3/8".No overhang required on right
side. Countertops shouldbe standard 36" high.
*Will fit minimum 30 1/4" cabinet opening.
STANDARD EXHAUST FAN
The standard350c.f.m.exhaust fan, included in the upper cabinetof your range, is factory-setto recirculate air throughacharcoal
filter.It can also beused to outside-ventexhaustif there isnot morethan one 90 degree elbow ormore than ten feetbetween the
rangeandtheoutside wall.Thisfanexhausts air onlyfrom the back of therangecabinet itcannotbe adapted for top-venting.
EXHAUST OUTLET LOCATION
Height from floorto center of duct opening is 62 5/8". From left base cabinet countertop overhang to center of duct opening is
14". If installing a four burner range into a 30 1/4" opening, dimension should be 8 5/8". Height from floorto center of duct
opening is 60 5/8" for short leg models.
#1518 OPTIONAL IN-LINE EXHAUST BLOWER
The optional in-line exhaust blower replaces the standard 350 c.f.m. exhaust fan provided in your range cabinet, and is to be in-
stalled by your contractor where your exhaust ducting exits the house. The inline blower should be ordered when you purchase
your range - the range and wiring must be modified to accommodate the blower. (The blower can be shipped in advance of the
range for installation additional shipping charges will apply.)
If you are outside-venting your range with more than 10 feet of ducting, or more than one elbow or if you simply prefer a more
powerful exhaust system you should include the optional 636 c.f.m. in-line exhaust blower. The#1518 In-LineBlower exhausts
smoke andcooking odors quickly and quietly, exitingthehouse upto 35 feet fromthe range. Ifdesired, the blower can be mounted
inthe basement orattic forpowerful, whisper-quiet operation.
The blower can be mounted vertically, horizontallyor at any angle.
Backward-curved airfoil blades move maximum air with minimal sound.
Fan and motor are precision balanced forquiet vibration-free operation.
Blower wiring attaches to the junctionbox on the back of your range.
SPECIFICATIONS:
636 cubic feet / minute 210 Watts, 115 Volts, 1.85 Amps, 60 Hz Blower length: 9-1/8"
Blower diameter: 13-1/2" (electricalbox protrudes1-3/4"D X 4-1/2"W from side ofblower) Inlet / outlet: 8"
Warranty:One year
IN-LINE EXHAUST BLOWER KIT CONTAINS:
Exhaust blower with 8" inlet and outlet
Adapter elbow attaches to back of range, converts range outlet to 3-1/4" X 10" standard duct size.
Duct adapter converts 3-1/4" X 10" duct to 8" round duct
Back draft damper with spring return prevents cold air from entering house when blower is not in use.
Outside louver grill covers the exhaust outlet at soffit or foundation wall.
Louvers automatically close when the blower is not in use.
Duct extender mounts to back of range cabinet, replacingdeflector plate.
Duct pipe, roof flashingand roof cap (if required) are not included.
WARRANTY
One-year warranty, covering parts andlabor. Additional four-year warranty (five years total) parts only on range / wall oven
burners and elements, fridgesealed refrigeration unitand compressor, and microwave magnetron tube.
NOTE
The January98 electricalstandard requiresthat a fourwire range cord beusedin all new construction. Please adviseif a threewire
rangecord isrequired (usedonlyinexisting construction).The electricalreceptacle and gaspipingshould beinstalledapproxi-
mately 4”above the floorand15”to the rightof the left edge of the cabinetopening (as youarefacingtheopening).
All 220V ranges come with standard four wire range cords attached.
ALL DIMENSIONS ARE FOR PLANNING PURPOSES ONLY
Specifications are subject to change without notice. We reserve the right to make product changes as required,
without notice. Consult installation instructions before cutting cabinets, counter tops or exhaust outlet.
SAFETY & EFFICIENCY
Elmira Stove Works appliances meet or exceed the most stringent U.S. and Canadian safety and efficiency standards.
Attic In-Line Exhaust Blower Installation
The in-line blower and ducting can be mounted to or between (allowing for
14" blower diameter) structural joists. Alternate installation: The exhaust
duct can extend straight up through the roof (similar to Installation #3). This
method will require a roof flashing and cap, not included.
Basement In-Line Exhaust Blower Installation
The exhaust duct runs down the wall behind the range into the basement,
where it exits through the foundation wall. The in-line blower and ducting
can be mounted to or between (allowing for 14" blower diameter) structural
joists.
Roof In-Line Exhaust Blower Installation
(straight up from cabinet)
Log homes and homes with a cathedral ceiling often require a top-ducted
exhaust. Advise your dealer if you are using this application a 7" round
hole must be made in the top center of your range cabinet. We highly recom-
mend locating your range in the kitchen prior to cutting the hole in the roof.
(Ducting can also be routed through kitchen cabinets above the range, if de-
sired.) 7" duct pipe, 7" to 8" increaser, roof cap and roof flashing are not in-
cluded.
Antique_Range_Specs:Layout 1 5/22/08 2:29 PM Page 1

Summary of content (1 pages)