Edition: 12.2009 · 610.44479.40.000 Original operating instructions · English Extra instruction manual G-BH1 Supplement to instruction manual 610.44434.40.
reg. 1 Safety reg. 1.3 Contents reg. 1 Safety ...................................................2 reg. 1.2 General safety instructions...........2 reg. 1.3 Other risks ....................................2 reg. 2 Correct Use Of The Equipment............2 reg. 3 Technical Data .....................................4 reg. 3.1 Mechanical Data...........................4 reg. 3.3 Operating conditions ....................4 reg. 5 Installation ............................................4 reg. 5.
reg. 2 Correct Use Of The Equipment G-BH1 units Foreseeable misuse are equipped with RL 94/9/EG three-phase drive motors. For more detailed information please consult the motor manufacturer’s accompanying operating instructions. exist in the following formats: − single-impeller − two-impeller, two-stage (for increased pressure difference) − two-impeller, double flow. (for increased conveyance volumes). are designed for industrial plants. are designed for continuous operation.
reg. 3 Technical Data reg. 3 Technical Data reg. 3.1 Mechanical Data Temperature increase The temperature increase of the air outlet compared with the ambient air temperature stated in the tables in the standard operating manual are not valid for units in accordance with GL/ 94/9/EU The gas temperature at the pressure side interruptor of the unit must not exceed 125°C [257°F]. reg. 3.3 reg.
reg. 7 Operation reg. 5.2 Electric power connection Point 5.2 “Electric power connection” in the standard operating manual is no longer applicable in any way whatsoever. Information concerning this point must be removed from the motor’s accompanying documentation. reg. 7 Operation Start-up and switch-down See chapter 6 “Initial operation”, sub-chapter 6.2 “Start-up and switch-down”.
reg. 9 Maintenance reg. 9.1 Repairs / Troubleshooting Under normal operational conditions (max. +40ºC gas intake and ambient air temperature, permissible total pressure difference) the following apply: Interval Maintenance procedure weekly Remove dust deposits from unit. weekly (only biogas uses) Inspect unit for leaks One of the following procedures will suffice for the inspection: Check the unit for smears, ice formation, odours and noises resulting from leakage.
reg. 9 Maintenance reg. 9.3 Decontamination and document of compliance 13 Ancillaries WARNING WARNING Hazard presented by combustible, caustic or poisonous substances! Units/systems which have come into contact with hazardous substances must be decontaminated before being sent to a workshop! Danger of explosions. The bleeder resistance of the installed accessories must have < 106 Ohm to ground! 13.
Declaration of Conformity Declaration of Conformity EU declaration of conformity Manufacturer: Gardner Denver Deutschland GmbH P.O. Box 1510 D-97605 Bad Neustadt / Saale Responsible for documentation: Holger Krause P.O. Box 1510 D-97605 Bad Neustadt / Saale Designation: G-Series Side channel blower G-BH1 Types 2BH1 1..-7.D..-Z 2BH1 2..-7.D..-Z 2BH1 3..-7.D..-Z 2BH1 4..-7.D..-Z 2BH1 5..-7.D..-Z 2BH1 6..-7.D..-Z 2BH1 8..-7.D..-Z 2BH1 9..-7.D..-Z 2BH1 1..-7.G..-Z 2BH1 2..-7.G..-Z 2BH1 3..-7.G..
Form for statement on safety Form for statement on safety Statement on health safety and on the protection of the environment For the safety of our employees and to comply with statutory requirements on handling substances harmful to the health and the environment, this statement must be enclosed, fully completed, with each unit/system sent.
610.44479.40.
© Gardner Denver Deutschland GmbH 11 / 12 610.44479.40.
www.gd-elmorietschle.de er.de@gardnerdenver.com Gardner Denver Schopfheim GmbH Roggenbachstraße 58 79650 Schopfheim · Deutschland Tel. +49 7622 392-0 Fax +49 7622 392-300 Elmo Rietschle is a brand of Gardner Denver‘s Industrial Products Group and part of Blower Operations. Gardner Denver Deutschland GmbH Industriestraße 26 97616 Bad Neustadt · Deutschland Tel.