Installation guide

Gold Solo Whistle Installation Guide (EtherCAT and CAN) Installation
MAN-G-SOLWHIIG-EC (Ver. 1.403)
|www.elmomc.com
65
Table of Contents
4.10. User I/Os (J6)
The Gold Solo Whistle has six programmable digital inputs, two digital outputs and one analog
input.
4.10.1. Digital Inputs (J6)
Each of the pins below can function as an independent input. The inputs conform to the PLC
standard. TTL configuration is available upon request.
For the pin table refer to Section 4.3.2.8.
Pin (J6) Signal Function
12 INRET1_6 Programmable input 1 6 return
13 IN1 Programmable input 1 (High speed)
14 IN2 Programmable input 2 (High speed)
15 IN3 Programmable input 3 (High speed)
16 IN4 Programmable input 4 (High speed)
17 IN5 Programmable input 5 (High speed)
18 IN6 Programmable input 6 (High speed)
Pin Positions
Table 23: Connector J6 Digital Input