Data Format Specifications
This command is executed in the form of 1-command/1 packet. The next command is not
accepted until the previous processing is completed.
The communication command always starts with STX (Start of Text) , and ends with ETX
(End of Text) .
If the communication format or command name is wrong, NAK (Negative
Acknowledgement) will be sent from this product.
When the communication format is correctly received, this product sends ACK (Normal
Acknowledgement).
Transmission command (PC Ceiling Presenter)
Each operation command is executed in ASCII code, and transmitted in a set of 7 bytes as
follows:
S
T
X
E
T
X
Command
(
PC
)
(Ceiling
Presenter
)
ACK
Data
Parameter
Connection
If the RS-232C cable is not correctly connected between this product and the PC, no
acknowledgement is transmitted. Connect the RS-232C cable correctly, and fix it firmly with
the connector set screws before the operation.
Transmission Specifications
Full duplex start-stop sync. mode
Start bit : 1 bit
Data bit : 8 bits
Stop bit : 1 bit
Parity bit : None
X parameter : None
Baud rate (Communication speed) : 9600bps