7. SETTING OF ALARM IN-OUT
When each of the ALARM IN terminals <1> and <2> are short-circuited to the GND
terminal, the Signal IN mode is established, and the Camera moves to the preset position set
in the OSD menu beforehand.
(1) Setting of the preset position for the ALARM IN terminals <1>, <2> (Refer to P. 27)
(2) Lock mode when input is in the ALARM IN terminal <1> (Refer to P. 27)
When input is made into either of the ALARM IN terminals <1> and <2> and the preset
operation is completed, the alarm signal is outputted form the ALARM OUT terminal <1>
for the time set in the OSD menu beforehand.
(1) Setting the time for the ALARM OUT terminal <1> (Refer to P. 27)
(2) Signal specifications for the ALARM OUT terminal <1>
Open collector output: Max. 12V, 30mA
When set so in the OSD menu, the signal output from the ALARM OUT terminal <2>
(EXTERNAL OUT terminal) can be turned ON/OFF by pressing the
AUX button on
the wireless remote controller.
(3) Setting the time for ALARM OUT terminal <2> (Refer to P. 27)
(4) Signal specifications for ALARM OUT terminal <2>
Open collector output: Max. 12V, 30mA
6
ALARM IN-OUT terminal (6P connector (black))
Note: When connecting with external equipment, observe the rated range.
[1] Alarm Input
[2] Alarm output
Code Color
Blue
Purple
Gray
White
Black
Pink
1
2
3
4
5
6
Pin No.
Terminal Name
ALARM IN1
GND
GND
ALARM IN2
ALARM OUT1
ALARM OUT2
IN <1> No-voltage make contact
Signaling System
No-voltage make contact
Open collector output
Open collector output
IN <2>
OUT <1>
OUT <2>