Instruction manual

- 29 -
Transmission specifications
Transmission mode : Synchronous half duplex
Transmission speed : 9600bps
Start bit : 1 bit
Stop bit : 1 bit
Parity bit : None
8. SETTING OF RS-485
By wiring and connecting the RS-485 terminal of the 5P connector (white) with the RS-485
control, this Camera can be controlled.
By setting the ID address for the RS-485 communication in each Camera, up to 223
Cameras can be controlled by a single PC or controller.
To assure the reliability, connect DATA(+) and DATA(-) with a shielding twist pair wire.
To protect the Camera main unit and the controller, be sure to turn OFF all the equipment
before starting connection.
RS-485 terminal (5P connector (white))
Code Color
Brown
Red
Orange
Yellow
Green
1
2
3
4
5
Signal Name
DATA(+)
DATA(-)
DATA(+)
DATA(-)
GND
Signal Function
+ side: To input the transmitted/received data
- side: To input the transmitted/received data
+ side: To output the transmitted/received data
- side: To output the transmitted/received data
GND
Pin No.
[1] Setting the terminating resistance (Refer to P. 21)
For the telecommunication equipment to be connected to the RS-485 interface, a
terminating resistance should be attached to both ends of the equipment having the longest
route to prevent signal damping.
Set the terminating resistance contained in the Camera to [ON/OFF] by selecting [MAIN
CONTROL] [RS-485END] in the OSD menu.
[2] Setting the ID address (Refer to P. 21)
Set the ID address for the RS-485 transmission to [1 223] by selecting [MAIN
CONTROL] [RS-485ID] in the OSD menu.
For the information of the data format specifications and command list, please contact our
dealer.