User guide

The following CAN emergencies are supported in PVT/PT modes:
Error
Code
(Hex)
Error
Code
(Dec)
Reason
Data Field
0x56 86 Queue is low. Number of yet unexecuted
PVT table rows has dropped below the
value stated in MP[4].
Field 1: Write pointer
Field 2: Read pointer
0x5b 91 Write pointer is out of physical range
([1…64]) of PVT table. Reason may be an
improper setting of MP[6].
Value of MP[6]
0x5c 92 PDO 0x3xx is not mapped.
0x34 52 An attempt has been made to program
more PVT points than are available in
queue.
Field 1: Index of PVT table
entry that could not be
programmed
0x7 7 Cannot initialize motion due to bad setup
data. The write pointer is outside the range
specified by the start and end pointers.
0x8 8 Mode terminated and motor has been
automatically stopped (in MO=1).
Data field 1: Write pointer
Data field 2:
1: End of trajectory in non-
cyclical mode
2: A zero or negative time
specified for a motion interval
3: Read pointer reached write
pointer
0x9 9 A CAN message has been lost.
Table 13-4: PVT CAN Emergency Messages
Note: Setting a new value for object 0x2F21 deletes all emergency events queued
for transmission.
Object description:
Index 2F21h
Name Emergency events
Object code VAR
Data type UNSIGNED16
Category
CANopen DS 301 Implementation Guide Manufacturer-specific Objects
MAN-CAN301IG (Ver. 2.1)