Instruction Manual

Gold Drum HV Installation Guide (EtherCAT and CAN) Technical Information
MAN-G-DRUMHVIG-EC (Ver. 1.202)
|www.elmomc.com
22
Table of Contents
3.2. Technical Data for 800 V Drive
Feature Units 35/800 50/800 R70/800 R100/800
Minimum supply voltage VDC *For S, T, or A option
= 95
Nominal supply voltage VDC 560 for 400 VAC
680 for 480 VAC
Maximum supply voltage VDC 780
Maximum continuous power
output
kW 22.5 32.5 45 65
Efficiency at rated power (at
nominal conditions)
% > 98
Auxiliary supply voltage option VDC 18 to 30 VDC (only in S, T, or A option)
Auxiliary power supply
VA ≤5 VA without external loading
7 VA with full external loading
Continuous current limit (Ic)
Amplitude sinusoidal/DC
trapezoidal commutation
A 35 50 70 100
Continuous RMS sinusoidal
commutation current limit (Ic)
A 25 35 50 71
Peak Current A 70 100 No Peak No Peak
Weight g (oz) 1.65 Kg (58.202 oz)
Dimensions mm (in) 180 x 142 x 75.2 (7.08" x 5.53" x 2.96")
Digital in/Digital out/ Analog in
6/4/1
Mounting method Panel / Wall Mounted
For both above Technical Data tables
*See page 25 for details on the part number. The S, T, or A option appears in models where
there is a 24 V control supply. If there is a 0 or 1 option, the control power supply operates
from the main power.
Note on current ratings: The current ratings of the Gold Drum HV (High Voltage) are
given in units of DC amperes (ratings that are used for trapezoidal commutation or DC motors).
The RMS (sinusoidal commutation) value is the DC value divided by 1.41.