5.7. Safe Torque Off (STO)
The Gold Solo Trombone has two STO (Safe Torque Off) inputs.
5.7.1. STO Input Interfaces PLC and AP Modes
Feature Details
Suffix applicable S, 0, or AP
Type of input Optically isolated
Input current for all inputs Iin = 2 mA @ Vin = 12 V
High-level input voltage 12 V < Vin < 30 V
Low-level input voltage 0 V < Vin < 7 V
Minimum pulse width >3 ms
Figure 46: STO Input Schematic for S or 0 suffixes
Figure 47: STO Input AP Schematic