4.11.2. USB 2.0 Communication
The USB network consists of Host controller and multiple devices. The Gold Solo Trombone is a
USB Device.
Notes for connecting the USB communication cable:
Connect a mini USB cable.
D+ and D- are a twisted pair in the cable.
The maximum cable length is 5 m.
The cable shield should only be connected to Ground at the host.
The shield of the cable is connected to the shield of the connector used for
communications.
Pin Signal Function
1 USB VBUS USB VBUS 5 V
2 USBD- USB _N line
3 USBD+ USB _P line
5 USB COMRET USB communication return
Pin Positions