Manual

Gold Solo Trombone Installation Guide Technical Specifications
MAN-G-SOLTROIG (Ver. 1.3)
www.elmomc.com
93
5.1.8. Built-In Protection
Software error handling
Abort (hard stops and soft stops)
Status reporting
Protection against:
Shorts between motor power outputs
Shorts between motor power outputs and power input/return
Failure of internal power supplies
Over-heating
Continuous temperature measurement. Temperature can be read on-the-fly; a warning can
be initiated x degrees before temperature disable is activated.
Over/under voltage
Loss of feedback
Following error
Current limits
5.1.9. Status Indication
Two outputs for bi-color LEDs
5.1.10. Automatic Procedures
Commutation alignment
Phase sequencing
Current loop offset adjustment
Current loop gain tuning
Current gain scheduling
Velocity loop offset adjustment
Velocity gain tuning
Velocity gain scheduling
Position gain tuning
5.1.11. Accessories
Cable Kit, catalog number: CBL-GDCWHIKIT02 (can be ordered separately)
For further details, see the documentation for this cable kit (MAN-CBLKIT-GOLD.pdf ).