User guide

Gold Trombone Installation Guide (EtherCAT and CAN) Installation
MAN-G-TROIG-EC (Ver. 1.604)
www.elmomc.com
42
Figure 8: DC Brushed Motor Power Connection Diagram
Notes:
For best immunity, it is highly recommended to use a 4-wire shielded (not twisted) cable
for the motor connection. The gauge is determined by the actual current consumption of
the motor.
Connect the cable shield to the closest ground connection at the motor end.
Connect the cable shield to the closest PE terminal of the Gold Trombone.
Ensure that the motor chassis is properly grounded.
4.7.2. Main Power
Pin Function Cable Pin Positions
PE Protective Earth Power and Motor
VN- DC Negative Power input Power
VP+ DC Positive Power input Power
Table 9: Connector for Main Power
The DC power for the Gold Trombone is delivered from a separated rectifying unit (supplied by
the user). Elmo recommends using the Tambourine rectifier specifically designed for use with
Elmo drives which offers a range of versatile options.