Installation Guide User guide

Solo Guitar Installation Guide Technical Specifications
MAN-SOLGUIIG (Ver. 1.403)
www.elmomc.com
58
4.3. Power Ratings
Feature Units
20/48
35/48
20/60
25/60
35/60
20/100
25/100
3/200
6/200
10/200
17/200
R45/48
R45/60
R35/100
R30/200
Minimum supply
voltage
VDC 11 11 14 23 46 11 14 23 46
Nominal supply voltage VDC 42 42 50 85 170 42 50 85 170
Maximum supply
voltage
VDC 48 48 59 95 195 48 59 95 195
Maximum continuous
power output
W 400 1300
960 1200
1700
1600 2000
480 960 1600
2700
1700 2200
2800
4800
Efficiency at rated
power (at nominal
conditions)
% > 97
Maximum output
voltage
97% of DC bus voltage at f=22 kHz
Amplitude
sinusoidal/DC
continuous current
A 20 35 20 25 35 20 25 3 6 10 17 45 45 35 30
Sinusoidal continuous
RMS current limit (Ic)
A
14.1 25 14.1
17.7 25 14.1 17.7 2.12 4.2 7 12 32 31.8 24.8 21.2
Peak current limit
A 2 x Ic No peak
Weight g (oz) 200 g (7.05 oz)
Dimensions mm
(in)
80 x 61 x 46.7
(3.15" x 2.4" x 1.84")
Digital in/Digital
out/Analog in
5/4/1
Note on current ratings: The current ratings of the Solo Guitar are given in units of DC
amperes (ratings that are used for trapezoidal commutation or DC motors). The RMS
(sinusoidal commutation) value is the DC value divided by 1.41.
4.3.1. Auxiliary Supply
Feature Details
Auxiliary power supply Isolated DC source only
Auxiliary supply input voltage 12 VDC to 195 VDC
Auxiliary supply input power < 7.5 VA (this includes the 5 V/2x200 mA load for
the main and auxiliary encoders)