3.3.2.2. Non-S 400 VDC Type Drives
Pin Function Cable
Not used
VL- N.C.
VL+ N.C.
Power
VP+ Pos. Power input DC Power
VN- Neg. Power input DC Power
PE Protective earth DC Power
Motor AC DC
PE Protective earth Motor Motor
M1 Motor phase Motor N.C
M2 Motor phase Motor Motor
M3 Motor phase Motor Motor
Connector Location
Table 3: Connectors for Main DC Power and Motor Cable – in Non-S 400 VDC type drives
Note: When connecting several motors, all the motor phases must be connected in an
identical sequence.