Installation Guide User Manual
Solo Trombone Installation Guide Technical Specifications
MAN-SOLTROIG (Ver. 1.203)
www.elmomc.com
65
• Buffered and differential outputs of the main encoder with up to 5 MHz pulses
• Buffered and differential outputs of the auxiliary encoder
• Emulated Buffered and differential outputs of resolver or analog encoder
• Pulse and Direction inputs (Differential)
• PWM current command output for torque and velocity
4.1.7. Built-In Protection
• Software error handling
• Abort (hard stops and soft stops)
• Status reporting
• Protection against:
Shorts between motor power outputs
Shorts between motor power outputs and power input/return
Failure of internal power supplies
Over-heating
Continuous temperature measurement. Temperature can be read on the
fly; a warning can be initiated x degrees before temperature disable is
activated.
Over/Under voltage
Loss of feedback
Following error
Current limits
4.1.8. Accessories
• Heat sinks (TBD)
4.1.9. Status Indication
• Bi-color LED