Software Manual Owner manual

SimplIQ Software Manual Unit Modes
MAN-SIMSW (Ver. 1.4)
10-11
10.5 Unit Mode 5: Single Feedback Mode
Single feedback mode is used when the same sensor is used for speed, commutation and
position. This situation is common with sensors that contain a single position sensor.
Software
position
command
Σ
Enable if
RM==1
Auxiliary position
command
Stop
manager
Stop and limit
switches
Smoother
d/dt
Position
Controller
FF[2]
Σ
Σ
main feedback
encoder
Speed
Estimator
--
Σ
DV[3]
DV[2]
Speed
Error, for the
speed controller
d/dt
Acceleration
feed forward
FF[1]
Position
correction
Figure 10-10: Single Feedback Mode (UM=5)
The position and speed command are generated by:
The position software command generator
The position auxiliary command generator
The position stop manager
The generation of the position and speed commands is described in Chapter 11.
The speed command, multiplied by the gain F[2], is fed as reference to the speed
controller, in addition to position correction. Setting FF[2] exactly to unity prevents
steady-state constant-speed tracking errors. The acceleration of the position command,
multiplied by FF[1], can be injected directly as a torque command. By default, FF[1]=0.
The reference values to the position, speed and torque controllers can be queried by
DV[3], DV[2] and DV[1] respectively.