User manual

SmartProg2
In-system serial programming by SmartProg2
For general definition, recommendation and direction about ISP see section Common notes
/ ISP please.
Description of SmartProg2 ISP connector
As ISP connector is used 10 pins connector 1-1634689-0 from TE connectivity or other
compatible connector.
1
2
3
4
5
6
7
8
9
10
Front view at ISP connector of programmer.
Specification of ISP connector pins depends on the device, which you want to program. You
can find it in the control SW for programmer (PG4UW), menu Device / Device Info (Ctrl+F1).
Be aware, the ISP programming way of respective device must be selected. It is indicated by
(ISP) suffix after name of selected device.
These specifications correspond with application notes published of device manufacturers.
Used application notes you may find on
www.elnec.com, section Support / Application
Notes.
Note: Pin no. 1 is signed by triangle scratch on ISP cable connectors.
As ISP connectors are used 10 pins connectors 09185107813 from Harting or other
compatible connector.
SmartProg2 ISP cable
Warnings:
When you use SmartProg2 as ISP programmer, don’t insert device to ZIF socket.
When you program devices in ZIF socket, don’t insert ISP cable to ISP connector.
Use only attached ISP cable. When you use other ISP cable (other material, length…),
programming may occur unreliable.
SmartProg2 can supply programmed device only, but target system cannot supply
SmartProg2.
SmartProg2 apply programming voltage to target device and checks his value (target
system can modify programming voltage). If the programming voltage is different as
expected, no action with target device will be executed.
49