User manual

ELNEC s. r. o.
You can edit the associated file name in file name box, put a full pathname. The control
program checks the present of this file on the disk. Also is possible enabling or disabling
automatic load of this file.
You can save both settings i.e. associated file and enabling of automatic load of this file to
disk by command File / Exit and save.
Device / Device options / Special options
The special terms used here are exactly the terms used by manufacturer of respective chip.
Please read the documentation to the chip you want to program for explanation of all used
terms.
If the name of this menu item is starting by "View/Edit ...", then the Read device command will
read the content of the chip configuration and it can be viewed and edited by this menu
command.
Device / Blank check
This command allows to blank check of all devices or its part if possible. The control program
reports a result of this action by a write of a warning message to INFO window.
The menu command Device / Device options / Operation options allows to set another
working area as the standard.
Device / Read
This command allows to read all device or its part into the buffer. The read procedure can
also read the content of the chip configuration (if it exists and is readable). The special device
configuration areas can be viewed or edited in dialogs available by menu View / Edit buffer
and menu Device / Device options / Special options (Alt+S).
The control program reports a finish of Read action by writing a message to INFO window.
The menu command Device / Device options / Operation options allows to set another
working area as the standard. Setting an option Verify data after reading in this menu
command means a higher reliability for device reading.
Device / Verify
This command compares the programmed data of the all device or its part with data in buffer.
The control program reports a result of verify operation to Info window and Log window.
The menu command Device / Device options / Operation options allows to set another
working area as the standard.
Setting in dialog General options (menu Options / General options) in tab Errors allows to
control, how to write the found errors to user specified report file. Also first 45 found errors
are written to Log window.
Note:
Verify operation compares content of the whole chip with the data in the software,
therefore it might happen - in case of incomplete programmed chip - the verification after
programming shows none error, but solo verify operation does not pass.
126