User guide
USB HID Keyboard Emulation Swipe Reader 
14
RESULT CODE 
This one-byte field contains the value of the result code. There are two types of result codes: 
generic result codes and command-specific result codes. Generic result codes always have the 
most significant bit set to zero. Generic result codes have the same meaning for all commands 
and can be used by any command.  Command-specific result codes always have the most 
significant bit set to one. Command-specific result codes are defined by the command that uses 
them. The same code can have different meanings for different commands. Command-specific 
result codes are defined in the documentation for the command that uses them. Generic result 
codes are defined in the following table. 
Value Result Code  Description 
0 SUCCESS  The command completed successfully. 
1 FAILURE  The command failed. 
2 BAD_PARAMETER  The command failed due to a bad 
parameter or command syntax error. 
GET AND SET PROPERTY COMMANDS 
The Get Property command gets a property from the device. The Get Property command 
number is 0. 
The Set Property command sets a property in the device. The Set Property command number 
is 1. 
The Get and Set Property command data fields for the requests and responses are structured as 
follows: 
Get Property Request Data: 
Data Offset  Value 
0 Property ID 
Get Property Response Data: 
Data Offset  Value 
0 – n Property Value 
Set Property Request Data: 
Data Offset  Value 
0 Property ID 
1 – n Property Value 
Set Property Response Data: 
None 
The result codes for the Get and Set Property commands can be any of the codes list in the 
generic result code table. 