User guide
Section 4. USB Communications
17
bus bandwidth used by the device, and slowing down the card data transfer 
rate decreases the USB bus bandwidth used by the device. This property is 
stored in non-volatile EEPROM memory so it will not change when the unit is 
power cycled. The value of this property, if any, will be sent to the host when 
the host requests the device’s USB endpoint descriptor. When this property is 
changed, the unit must be power cycled to have these changes take effect for 
the USB descriptor. If a value other than the default value is desired, it can be 
set by the factory upon request. Examples follow: 
Example Set POLLING_INTERVAL property Request (Hex): 
Cmd Num  Data Len  Prp ID  Prp Value 
01 02 02 0A 
Example Set POLLING_INTERVAL property Response (Hex): 
Result Code  Data Len  Data 
00 00  
Example Get POLLING_INTERVAL property Request (Hex): 
Cmd Num  Data Len  Prp ID 
00 01 02 
Example Get POLLING_INTERVAL property Response (Hex): 
Result Code  Data Len  Prp Value 
00 01 0A 
TRACK_ID_ENABLE PROPERTY 
Property ID:  3 
Property Type:  Byte 
Length: 1 byte 
Get Property:  Yes 
Set Property:  Yes 
Default Value:  95 (hex) 
Description:  This property is defined as follows: 
id  0  T
3
T
3
T
2
T
2
T
1
T
1
Id  0 – Decodes standard ISO/ABA cards only 
  1 – Decodes AAMVA, CA DL/ID and 7-bit cards also 
T
#
00 – Track Disabled 
  01 – Track Enabled 
  10 – Track Enabled/Required (Error if blank) 
This property is stored in non-volatile EEPROM memory so it will not change when the unit is 
power cycled. When this property is changed, the unit must be power cycled to have these 
changes take effect. If a value other than the default value is desired, it can be set by the factory 
upon request. 