User guide
Section 4. USB Communications
19 
01 02 03 08 
Example Set MAX_PACKET_SIZE property Response (Hex): 
Result Code  Data Len  Data 
00 00  
Example Get MAX_PACKET_SIZE property Request (Hex): 
Cmd Num  Data Len  Prp ID 
00 01 03 
Example Get MAX_PACKET_SIZE property Response (Hex): 
Result Code  Data Len  Prp Value 
00 01 08 
INTERFACE_TYPE PROPERTY 
Property ID:  16 (10 hex) 
Property Type:  Byte 
Length: 1 byte 
Get Property:  Yes 
Set Property:  Yes 
Default Value:  0 (HID) 
Description:  The value is a byte that represents the devices interface type. The value can 
be set to 0 for the HID interface or to 1 for the keyboard emulation interface. 
When the value is set to 0 (HID) the device will behave as described in the 
HID manual. When the value is set to 1 (keyboard emulation) the device will 
behave as described in the keyboard emulation manual. This property should 
be the first property changed because it affects which other properties are 
available. After this property is changed, the device should be power cycled 
before changing any other properties. This property is stored in non-volatile 
EEPROM memory so it will persist when the unit is power cycled. When this 
property is changed, the unit must be power cycled to have these changes take 
effect. If a value other than the default value is desired, it can be set by the 
factory upon request. Examples follow: 
Example Set INTERFACE_TYPE property Request (Hex): 
Cmd Num  Data Len  Prp ID  Prp Value 
01 02 10 00 
Example Set INTERFACE_TYPE property Response (Hex): 
Result Code  Data Len  Data 
00 00  
Example Get INTERFACE_TYPE property Request (Hex): 
Cmd Num  Data Len  Prp ID 
00 01 10 
Example Get INTERFACE_TYPE property Response (Hex): 