User`s guide
CARROLL TOUCH Appendix A - Error Messages
Touch System Diagnostics (CTDIAG) User’s Guide A-9
Message: The SBC controller type cannot be used 
with the Direct interface method
Meaning: A test is attempted with the SBC and the direct interface 
method selected.
Action: If the SBC controller is selected, the TAPI interface 
method must be selected.
Message: Touch did not de-activate. Touch is 
still enabled.
Meaning: An attempt was made to disable the touch using the 
SetTouchMode
 command.
Action: Select Debug from the Test Menu and examine the 
Trace history to determine more about the condition.
Message: Touch System Initialization Failed
Meaning: CTDIAG cannot successfully complete initialization.
Action: Select Debug from the Test Menu and examine the 
Trace history to determine more about the condition.
Message: Touch System Init Failed - Corrupted 
Report Received
Meaning: An expected report was corrupted during initialization.
Action: Select Debug from the Test Menu and examine the 
Trace history to determine more about the condition.
Message: Touch System Init Failed - Expected 
Report Not Received
Meaning: An expected report was not received during 
initialization.
Action: Select Debug from the Test Menu and examine the 
Trace history to determine more about the condition.
Message: Touch System Init Failed - Unable To 
Open Com Port
Meaning: The touch system cannot communicate with the comm 
port correctly. This error usually occurs on the first 
attempt to initialize the touch system. 
Action: Check for the correct comm port and I/O address 
specified on the command line.
Table A-1. Error Messages (Continued)