Battery LED (during normal operation of the device without the charger connected):
Off – battery fully discharged or fully charged (if the status LED blinks)
Blinking yellow - battery discharged in 70%
Blinking red – battery discharged in 85%
Continuous red – battery discharged - device will be switched off
Status LED
Off – the pedestrian module is switched off
Blinking green – the pedestrian module is active
Blinking yellow - the acknowledge mode is active
Blinking red – the auto-test is active
Continuous red – pedestrian module failure or not configured
Acoustic and vibration signals
The alarm/warning mode – the frequency and level may be configured from the application
level.
3 short signals every 5 seconds Low battery level, less than an hour to be completely
discharged.
Continuous signal for 10 seconds – the device is discharged, automatic switching off.
Continuous signal when the Q button is pressed and held the device is switched off; the
button may be released.