Instruction Manual

Instruction manual I ELOshield
Rev. 20 09.03.2020 Page 35 of 85
Assigning the X2, 6 x 0.34 wire
Signal desig-
nation
Wire color Technical data Comments
DOUT1 NO Green Relay 1
Normally open contact
Connected with the breach of
the inner (red) zone in the
default configuration
DOUT1 NC Brown Relay 1
Normally closed contact
Connected with the breach of
the inner (red) zone in the
default configuration
DOUT1 CM Yellow Relay 1
Switching contact
Connected with the breach of
the inner (red) zone in the
default configuration
DOUT1 NO Pink Relay 2
Normally open contact
Connected with the breach of
the outer (yellow) zone in the
default configuration
DOUT1 NC Gray Relay 2
Normally closed contact
Connected with the breach of
the outer (yellow) zone in the
default configuration
DOUT1 CM White Relay 2
Switching contact
Connected with the breach of
the outer (yellow) zone in the
default configuration
Table 3.Identification of wires in X2 group
6.6.2 Example connections in X1 group
Example 1: ELOshield is permanently activated.
Pink and red wire are connected to the power supply voltage of +12 VDC … +48 VDC
Blue and gray wires are connected to the ground
Example 2: ELOshield is permanently activated (option two).
Red wire is connected to the power supply voltage of +12 VDC … +48 VDC
Blue wire is connected to the ground
Pink and gray wires are not connected (or connected to the ground)
The input 1 logic is configured as "normal" in the software.