Instruction Manual

Instruction manual I ELOshield
Rev. 20 09.03.2020 Page 60 of 85
Signaling and zone settings
o Zone 1 (alarm) buffer the first zone radius expressed in
centimeters, by which alarm zone generated by antenna
modules (A) is extended (min. 0 cm, max. 1,500 cm).
o Zone 2 (warning) buffer the second zone radius
expressed in centimeters, by which warning zone
generated by antenna modules (A) is extended (min. 0 cm,
max. 1,500 cm).
o LEDs brightness – indicates the light intensity in
percentage as generated by LEDs.
o Signaling reactions to different types of devices: vehicle and stationary modules.
o First zone sound intensity – indicates the sound signal loudness in percentage as
generated by the pedestrian module,
when it is in the alarm zone.
o Second zone sound intensity –
indicates the sound signal loudness in
percentage as generated by the
pedestrian module, when it is in the
warning zone.
o First zone sound pulsation – indicates
the single sound duration as
generated by the pedestrian module,
when it is in the alarm zone.
o Second zone sound pulsation –
indicates the single sound duration as
generated by the pedestrian module,
when it is in the warning zone.
o First zone vibration rate – specifies the vibration rate of the pedestrian module,
when it is in the alarm zone.
o Second zone vibration rate – specifies the vibration rate of the pedestrian module,
when it is in the warning zone.
o First zone blinking frequency – indicates the red LED blinking frequency, when the
pedestrian module is in the alarm zone.
o Second zone blinking frequency – indicates the yellow LED blinking frequency, when
the pedestrian module is in the warning zone.