Rev. 20 09.03.2020 Page 74 of 85
3. Action 2 checks if status variable 0 (muting mode) is active and if zone 2 has been breached
by any module or device, the result is stored in status variable 2.
4. Action 3 checks the value of status variable 1. If the value of the status variable is equal to 1,
relay 1 is activated, if not – the relay is deactivated.
5. Action 4 checks the value of status variable 2. If the value of the status variable is equal to 1,
relay 2 is activated, if not, the relay is deactivated.
6. Action 5 checks if muting mode 1 or 2 is active, if so the antenna modules (B) are
deactivated.
7. Action 6 checks if muting mode 2 is active, if so – the antenna modules (A) are deactivated.
8. Action 7 checks the value of status variable 1. If the value of status variable is equal to 1, OC
1 output is activated, if not – OC 1 output is deactivated.
9. Action 8 checks the value of status variable 2. If the value of status variable is equal to 1, OC
2 output is activated, if not – OC 2 output is deactivated.
Example 2:
The stationary set (with the antenna module (B)) opens the gate only for specific vehicles (with
antenna module (A)):
1. For every vehicle for which the gate should open, e.g., LSB bit 0 should be set as in the below
figure. The LSB bits are set in the settings tab of the device.
2. In the configuration of the stationary panel the action should be set so that relay 1 reacts to
the vehicle in zone 1 and to LSB bit 0.
3. Relay 1 is connected to the gate automatic control system.
Example 3:
Breach of zone 1 of the stationary set (with antenna modules (A)) by the pedestrian module makes
the vehicle in zone 2 slow down and the vehicle in zone 1 stop (the vehicle is equipped with the
antenna module (A)) and activate the visual signal by the stationary module:
1. The stationary module actions are configured so that after detecting the pedestrian module
MSB bit 0 is sent by the antenna modules (B) and relay 1 activates the visual signal: