User's Manual

Proximity BUS Reader Installation Guide
www.elpas.com
Page 4 of 6
V10/March 2014
Electrical Specifications
Frequency
Low frequency electromagnetic field (125 KHz)
ISO Card Standard
EM 4100
*Read Range
Up to 10 cm/4.0 inches (actual range depends on the proximity card or tag)
RS-485 BUS
230Kbit/sec
Device Supervision
Lost Away, Low Voltage, RS-485 BUS Communication Problem
Red LED Indicator
Unregistered in Eiris/ELC Programmer - Flashes once/second
Power up/RS-485 Communication Loss - Flashes once/second
Status LED
Software configurable
Inputs/Output
Two dry contact analog inputs (N.O.) One dry contact open collector digital output (up to 100mA)
Input Supervision
4 Levels (Open, Closed, Line Short, Line Cut) using optional Elpas End-of-Line Terminator
(Elpas End Of Line Terminators have not been evaluated for use in UL Applications)
Power Requirements
1228VDC, 48mA @ 24VDC
General Specifications
Construction
White polycarbonate plastic (IP-67)
Device Interfaces
RS-485 Bus & Power: 2 meter/6.5ft in length, 6-wire AWG 26 cable with male RJ-11 (6P6C) connector
Input/Output : 2 meter 2 meter/6.5ft in length, 4-wire AWG 22 cable with ends
Dimensions (H x W x D)
116 x 70 x 16.8mm…(4.5 x 2.76 x 1.62 inches)
Weight
121.5 grams (4.3 ounces)
Operating Environment
Temp: -20°C to 50°C (-4°F to 122°F)…...Humidity: 20% to 100% non-condensing
Minimum Distance
Between Readers
30cm/ 12 inches
Management software
Eiris 4.7.1 (or higher) Software
*Actual read range depends on card/tag type, electrical environment and proximity to metal. Specifications are subject to change without notice.
Selected Compatible Accessories
Part Number
Description
3-6302-2
White proximity reader replacement cover (8 units)
3-6317-0
RDR-BACK, mounting spacer for metal surfaces
5-IOX00001
End-of-Line Terminator for Elpas & AXS Inputs (5 units)
5-JBA00485
RS-485 Junction Box, 4 RJ11 Ports
5-ERS02800
P60 Power Supply, 24VDC/2.2A