Chapter 6 Diagnostics
MAN_905G_1.16 Page 142
To write to a register double click with mouse on the
register and a pop up box will appear as shown below.
Enter value and press ‘OK’.
You can disable the links between the I/O registers and
the Ethernet interface by selecting “Disable Read Area”
and “Disable Write Area” - if you do this, remember
to re-enable before you leave the diagnostics screen.
Settings
You can change your TCP Connection
setting i.e. IP address and port.
Program / Load Unit
These options allow you to program and
upload the configuration from the module
via the Ethernet port. Must ensure the IP
address has been set on the module before
uploading the Configuration
Monitor Comms
Configuration software also provides the option to monitor the radio network
communications via the Ethernet port. This allows radio traffic to be monitored from any
location where an Ethernet connection to the 905G can be established. Simply select
‘Monitor Comms’ from the Network Debug Options section of the Ethernet Settings page.
Functionality is as per section 6.2.2c above.