User's Manual

Page 56 E2 Wireless I/O
30599
Spare
30600 Spare
30601
32500
General Purpose word Storage – Used for:
Staging area for data concentrator
Fieldbus Mappings storage
32501
36000
Not Available
36001
36008
Local Pulsed inputs 1-4.B.E Format.
Most significant word at lower / odd address.
36009
36040
spare
36041
38000
Not Available
38001
38032
Local Analog inputs as floating point values
Modscan Format (Sign + Exponent + Most significant 7 bits of
significant at Even / Higher Addressed location. Lower 16 bits of
Significant at lower / Odd addressed location)
(12.3 => 38001=CCCD, 38002=4144)
38033 - 38040 Spare space for floating point values
32501
40000
Not Available
“Holding Registers
40001
40002
Local AO1 – AO2
40003
40020
Spare
40021
40040
Locally attached 115smodules
(See 115S detail below)
40041
(space for up to 24 115S modules)