User's Manual

Table Of Contents
EA Mobile User Guide
6. Reading mode
58
• (bullet) indicates non-tampered
T indicates Tampered; If Reset Tamper is on, the endpoint will be
instructed to clear the tamper indication. The T or R result should appear
within a few seconds.
R indicates the Tamper reset successful; meter reading is not displayed
since it was displayed when the endpoint was initially read.
F indicates the Tamper reset failed; possible cause is a tilted meter that
will not allow the liquid tamper switch inside the endpoint to level for a
reset. Endpoint damage may also cause reset failure.
L indicates Leak Detection (for water endpoints only) - The L character is
displayed when a leak condition is detected using the leak detection
route sequence commands.
Address - Shows the street address for a given gas or water endpoint/
meter.