Installation and Operation Manual

Troubleshooting
Page 45
8 Troubleshooting
Issue Possible cause and remedy
No indicators are
illuminated
Check that the power supply is connected
correctly.
Check that the power supply is a 12V or 24V
supply.
The red error
indicator is flashing
There may be a problem with the VHF antenna sys-
tem. This can be confirmed using proAIS2. If the
'High VSWR' alarm is active please check for the fol-
lowing:
Faulty VHF antenna/cable/connectors
Poor connection at the VHF antenna/cable/
connectors
Suitability of the VHF antenna (for AIS only we
recommend antennas tuned to 162MHz / for
splitter variants we recommend antennas tuned
to 159MHz)
VHF antenna location (ensure that is isn't
mounted near other transmitting antennas or
sources of interference, metal structures, or
other obstructions)
The red 'error'
indicator is
illuminated
Check that the unit is programed with a valid
MMSI number. This can be confirmed using the
Configuration tab in proAIS2
Check that the GNSS antenna has a stable
position fix. This can be confirmed using the
GNSS Status tab in proAIS2
Check that the power supply is within 12 - 24V.
This can be confirmed using the Diagnostics tab
of proAIS2