In the event of a fire, the following may be formed :
- carbon monoxide (CO)
- carbon dioxide (CO2)
5.3. Advice for
f
ire
f
i
ght
er
s
No data available.
SECTION 6 : ACCIDENTAL RELEASE MEASURES
6.1. Personal precautions, protective equipment and emergency procedures
Consult the safety measures listed under headings 7 and 8.
For non first aid worker
Avoid any contact with the skin and eyes.
For first aid worker
First aid workers will be equipped with suitable personal protective equipment (See section 8).
6.2. Environmental precautions
Contain and control the leaks or spills with non-combustible absorbent materials such as sand, earth, vermiculite,
diatomaceous earth in drums for waste disposal.
Prevent any material from entering drains or waterways.
6.3. Methods and material for containment and cleaning up
Neutralise with an acidic decontaminant.
Clean preferably with a detergent, do not use solvents.
6.4. Reference to other sections
No data available.
SECTION 7 : HANDLING AND
S
TO
RA
GE
Requirements relating to storage premises apply to all facilities where the mixture is handled.
7.1. Precautions for safe handling
Always wash hands after handling.
Remove and wash contaminated clothing before re-using.
Ensure that there is adequate ventilation, especially in confined areas.
Emergency showers and eye wash stations will be required in facilities where the mixture is handled constantly.
Fire prevention :
Handle in well-ventilated areas.
Prevent access by unauthorised personnel.
Recommended equipment and procedures :
For personal protection, see section 8.
Observe precautions stated on label and also industrial safety regulations.
Avoid eye contact with this mixture at all times.
Packages which have been opened must be reclosed carefully and stored in an upright position.
Prohibited equipment and procedures :
No smoking, eating or drinking in areas where the mixture is used.
7.2. Conditions for safe storage, including any incompatibilities
Stock between 5 °C and 40°C in a dry, well ventilated place
Storage
Keep the container tightly closed in a dry, well-ventilated place.
The floor must be impermeable and form a collecting basin so that, in the event of an accidental spillage, the liquid cannot
spread beyond this area.
Packaging
Always keep in packaging made of an identical material to the original.