Babyhawk R Manual

EMAX Tiny Receiver Instruction
Specifications
Dimension: 16 × 9 × 3.3mm (L × W × H)
Weight: 0.55g
Number of Channels: Up to 8CH from SBUS (CH1~CH7 for PWM, CH8 RSSI for FC)
Operating Voltage Range: 3.7~6V
Operating Current: 50mA@5V
Compatibility: FrSky D8 mode
Binding Procedure
Binding is the process of uniquely associating a particular receiver to a transmitter
module. A transmitter
module can be bound to multiple receivers (not to be used simultaneously). A receiver
can only be bound
to one transmitter module.
1.Holding the bind button while power on the receiver. When the GREEN LED is on,
it means the receiver is in BIND MODE
2.Turn on the transmitter, set it into bind status. When the RED LED of the receiver
starts flashing, it means bind successful.
3.Turn on the transmitter again, the GREEN LED receiver will be on, it means the
receiver is receiving data from transmitter. Transmitter bind with receiver no need
repetitive operation, unless you change either receiver or transmitter.
F3 Magnum Mini Tower Instrction
The FC and ESCs of Babyhawk_Race are based on F3 Magnum Mini Tower System.
Please download the manual as the following link http://yinyanmodel.com/En/Down-
List.asp in our website for more details and information.