AIR DRYER INSTRUCTION MANUAL
3
READ PRIOR TO STARTING THIS EQUIPMENT
1. This equipment has been thoroughly checked, packed and
inspected before leaving our plant.
2. This equipment is shipped to accommodate a forklift truck. Use a
forklift when moving and installing this equipment. Never lift it by
hooking on to the air inlet and outlet connections.
3. Clearances: Leave at least 24 inches or more (61 cm) on either
side of the cabinet for free air flow. Air-cooled units need
adequate, free-flowing ambient air to flow across the refrigeration
condenser, so do not block. The ambient temperature is to be
within the operating parameters of 34°F (1°C) to 100°F (38°C).
4. Refrigerant capacities are posted on the data plate, on the outside
of the unit.
DESCRIPTION
Function
Compressed air enters the air-to-air heat exchanger and is pre-
cooled by the chilled outgoing air of the compressor. The air then enters
the air-to-refrigerant heat exchanger where it is further cooled by the
refrigeration system. As the air is cooled, water vapor condenses into
water droplets. The air and water droplets then enter the separator where
water is removed. In addition, the air is filtered of all solid particles 0.01
micron and larger. Clean, dry compressed air leaving the dryer
minimizes maintenance and repair, and also reduces internal dryer
contamination.