Product Manual

Polar Air Rotary Screw Compressors
13
Following replacement times are important for
safe operation. Remember to clear lifetime and
reset maintenance timer after replacements are
made. Refer to PLC manual for more details.
Maintenance Notifications
Component (PLC) Lifetime (hrs)
Air Filter
CAF
4000
Oil Filter
COF
4000
Air/Oil Separator Filter
CSF
4000
Lubricating Oil
C--=
4000
Check Compressor
C--h
4000
Motor Bearing Grease
BL
10,000
Resetting Maintenance Alarms
6. First screen for resetting alarms.
7. Press the two arrow keys at the same time
to bring up the Password Level Selection-
Press down arrow 2 times to select Level 3
then press enter.
8. Enter in the 6 Digit Password 6 6 6 6 6 6,
by using the Up Arrow to set the digit to 6
then press Enter to move to the next digit,
and press the Up Arrow to set to 6, repeat
until last digit is set to 6, then press Enter.
Press both Up & Down Arrows
again if the wrong password is entered.
9. Arrow down to 6)OIL/FILTER-HOURS
and press Enter.
10. CHANGE AIR FILTER shows in the
display and press Enter.
11. Using Enter move over to the SET:
number and change to 4000, using the Up
& Down Arrows. Then using the Enter
button, change NO to YES then press
Enter and hours are reset.
Use to navigate
through reset.
The Enter button used
to navigate through
resets.
Change NO to YES
Change to 4000