Emax Air Dryer REFRIGERATED TYPE COMPRESSED AIR DRYERS EDRCF1150029 – EDRCF4602000 Instructions Manual
TABLE OF CONTENTS 1. Important safety notes - Please read .......................... 1 1.1. Transportation ............................................................... 1 1.2 Positioning ..................................................................... 1 1.3 Installation ...................................................................... 1 1.4 Before operating ............................................................ 1 1.5 Maintenance by an engineer ......................................... 1 1.
I. IMPORTANT SAFETY NOTES – Please READ A) When operating the air dryer the operator must apply safe working methods and observe all local safety instructions and relevant regulations. B) Prior to installation, the dryer and the compressed air system are to be depressurized and disconnected from the electrical main supply. C) The user is responsible for safe operating conditions. Parts and accessories must be replaced if inspection shows that safe operation cannot be assured.
D) For air cooled dryers, clean the air condenser as soon as it’s dirty or clogged. E) For optional water-cooled condensers, use only clean water and install a water filter if needed. Use water counter flow to clean condenser if need. F) Check the trouble-shooting list in case of maintenance troubles. G) Check operating pressures, temperatures and time settings after maintenance. If operating and safety devices function properly, the air dryer may be used. 2.
down to dew point and enters the separator where condensates are collected. The outgoing chilled air is then warmed up in the economizer by the hot incoming air. b) The condensates are collected after centrifugal separation and drained out through the automatic trap. c) As long as the compressed air temperature does not drop below dew point, there will be no condensation in the air circuit. 5) Refrigerant compressor Being of the hermetic type, it requires no servicing.
3. OPERATION 3.1.
3.2. During Operation Regularly check the digital temperature controller ESD3 or dew point indicator on dryer. B) Start up and shut-down Warning: Avoid leaving the dryer off when compressed air is still flowing through it. C) Starting for the first time or after a long stop 1) Set the rotary switch to “I” This preheats the dryer and turns the drain system on. It is recommended to leave the dryer power on permanently so the crankcase heater runs continuously.
Emax Air Dryer REFRIGERATED TYPE COMPRESSED AIR DRYERS Technical Specifications & Diagram
Model Capacity (CFM) Connection Size Voltage Total Electric Power Refrigerant Type Pressure Drop Max Work Max pressure Ambient (bars) Temperatu Max inlet Temp. PDRCF1150029 29 1/2" 115 0.42 R134a <3 232 122 140 PDRCF1150058 58 3/4" 115 0.68 R134a <3 232 122 140 PDRCF1150115 115 1 1/2" 115 0.93 R134a <3 232 122 140 PDRCF1150144 144 1 1/2" 115 1.28 R134a <3 232 122 140 PDRCF2300288 288 2" 230 1.94 R134a <3 232 122 140 PDRCF4600288 288 2" 460 1.
5.
9
5.
Dryair DN40-US - Dryair DN80US Electrical Circuit 12
Dryair DN100-US - Dryair DN110-US Electrical Circuit 15
Dryair DN140-US - Dryair DN170-US Electrical Power Circuit 16
Emax Air Dryer REFRIGERATED TYPE COMPRESSED AIR DRYERS General Arrengements Main Settings Drawings
6. GENERAL ARRANGEMENTS Model Dryair DN10-US 1 * GKO50X + 1 * GKO50Y MKO50 KIT 16.26 14.29 21.93 70.40 Dryair DN20-US 1 * GKO50X + 1 * GKO50Y MKO50 KIT 16.26 14.29 21.93 70.40 Dryair DN30-US 1 * GKO50X + 1 * GKO50Y MKO50 KIT 16.26 14.29 21.93 70.40 Dryair DN40-US 1 * GKO150X + 1 * GKO150Y MKO150 KIT 18.62 17.83 32.76 112.20 Dryair DN50-US 1 * GKO150X + 1 * GKO150Y MKO150 KIT 18.62 17.83 32.76 116.60 Dryair DN60-US 1 * GKO150X + 1 * GKO150Y MKO150 KIT 18.62 17.83 32.
8.
Dryair DN40-US - Dryair DN60-US 20
Dryair DN70-US - Dryair DN90-US 21
Dryair DN100-US - Dryair DN110-US 22
Dryair DN140-US - Dryair DN150-US 23
Dryair DN160-US - Dryair DN170-US 24
Dryair DN30-US 25
Dryair DN50-US 26
Dryair DN70-US 27
Dryair DN80-US 28
Dryair DN110-US 29
Dryair DN140-US 30
Dryair DN160-US 31
Dryair DN170-US 32
9.
10. TROUBLESHOOTING Problem Possible Cause Repair Dryer is switched on, indicator light is lit but the refrigerant compressor does not turn on. The connection has inverted phases Invert two phases Refrigeration unit is not functioning Check refrigeration compressor The refrigerant high pressure protection has tripped The refrigerant safety high pressure switch has tripped. Comments 3-phase dryers are equipped with a phase controller to avoid the fans from turning in the opposite direction.
Problem Possible Cause Water in system Compressed Air Inlet and outlet connections are reversed. Check inlet and outlet connections. Drain system is clogged or inoperative. Restore a free flow of water condensate. Check water evacuation. Bypass system is open Check the valves Important: Bypass piping should be installed around the dryer so the dryer can be isolated for service without shutting down the air supply. During dryer operation, valves must be set so all air goes into the system.
Problem Possible Cause Repair Comments The unit will not run or cycles off and on. Excessive ambient temperature Designed conditions and correction factors are described in dryer . Be sure that dryer is working lower than design conditions. A high ambient temperature may cause the refrigerant system to operate at higher than normal pressures. Results will be a higher than normal evaporator temperature.