Product Manual

9
Operating Instructions
Maintenance Notifications
Component (PLC Name) Lifetime
Oil Filter (Oil) 0600 hrs.*
Air/Oil Separator Filter (O-G) 4000 hrs.
Air Filter (Gas) 0600 hrs.
Lubricating Oil (Lube) 0600 hrs.*
Motor Bearing Grease (Grease) 2000 hrs.
* Values shown above are factory set for max. lifetime parameters.
After initial oil change, max. lifetime parameters can be reset. Refer
to PLC manual for more details.
Following replacement times is important for safe
operation. Remember to clear lifetime and reset to 0
hours after replacements are made. The menu selec-
tion needed for this setting is found by scrolling to:
“Customer Parameter” then, “Clear Lifetime”
Refer to PLC manual for more details.
Figure 9: Mechanical System Components
8, 15
9
1
5
2
3
4
6
10
14
11
7
13
12
Side View
End View
Mechanical Components
1. Drive Motor
Drive motor is 4 pole with low RPM (1750). This motor
is also capable of variable speed drive as a standard fea-
ture. The motor is 12 lead, Y delta soft starting for low
amp draw. Overload protection is installed for safety.
Normal electric current can fluctuate slightly for various
reasons but if the current spikes, the overload protec-
tion will cause the motor(s) to stop. If this happens,
the motors must be reset manually.
Some reasons for overload protection:
a) Operator error: Improper regulation of air ex-
haust pressure or other parts of the system.
b) Mechanical failures:
• Internalmotorfailure
• Impropermotorphasing
• Systemsettingerror
• Blockedair/oilseparatorlter.
If motor overload protection is caused by any
other reason, contact EMAX immediately.
2. Variable Speed Drive (Energy saving device)
Ready Cabinet
This cabinet has allocated space and cooling fan
to house varible speed drive component. To con-
vert to Varible speed drive, contact EMAX custom-
er service for more information. 1-866-294-4153.
3. Air Suction Filter (Air Intake)
A dry type paper filter with filtration of 10 ppm. Replace
after first 600 hours of operation; then every 500-600
hours, depending on environment. Refer to the computer
controls of the compressor to monitor operating time and
remember to reset counter to 0 when filter is replaced.
There is an automatic alarm that can be set to remind
operator of service times.