Air Compressor Manual
EMAX Piston Air Compressors
13
1. Connect rst power lead to 1L1.
2. Connect second power lead to 3L2.
3. Connect third power lead to 5L3.
4. Connect ground wire to existing motor ground wire.
5. Check for proper motor rotation. When facing motor shaft, pulley should turn counterclockwise. If rotation is
reversed, turn off power then switch two power leads.
1. Make sure all operators receive product training, read and understand all instructions.
Three Phase Motors (See gure 7)
WARNING
Ensure wiring is installed according to voltage required for proper
motor operation (220V or 460V).
Keep all ammable, combustible, poisonous and noxious materials
away from operating area. Make sure there are no oily rags, trash,
leaves, litter or other combustible materials in operating area. Keep
suitable, fully charged re extinguishers nearby when servicing and
operating the compressor.
CAUTION
Safety Rules
Operation