Air Compressor Manual

EMAX Piston Air Compressors
3. Cap tting on cylinder heads if not using pilot valve for continuous run port.
4. Make sure there is a 1/4” copper tube (unloader tube) installed from tank check valve to unloader on
pressure switch. This relieves head pressure when compressor stops for easier restart. See gure 2.
5. Use proper pulley for motor. Refer to Pulley Size Chart for correct sizing.
6. Install belts. There should be 1/2” slack for proper belt tension. See gure 3.
7. Use a exible connector between compressor tank and piping system to minimize noise, vibration, unit
damage, and pump wear.
Pulley Size Chart
(Pulley size in inches)
Pump
Model No.
Electric
Motor - Hp
1750 RPM
4 Pole Motor
3450 RPM
2 Pole Motor
Gas Engine
Hp
APP2V0313S 3 5.5 2.75 5.5 3
APP3Y0518S 3 5.5 2.75 6.5 3
APP3Y0518S 5 5.75 2.75 6.5 3
APP3Y0521T 5 7 3.5 8 3.5
APP2V0732S 5 5.5 2.75 8 3
APP2I0524T 5 7.7 3.8 11 4
APP3Y0732T 5 6 3 11 3
APP3Y0732T 7.5 7 3.5 13 4
APP4V1043T 7.5 6.4 3.2 13 3.2
APP4V1043T 10 8.8 4.4 18 4.4
APP3Y1544T 10 9 4.5 24 4.5
APP3Y2062T 15 9 4.5 28 4.5
APP4V2598T 20 9 4.5 40 4.5
APP4V2598T 25 11.5 5.8 50 5.8
NOTICE
Splash lubricated pumps require 550 RPM for proper lubrication. Be
sure to size motor and engine pulleys correctly.