Product Manual
Oper
ating
Instructions
9
Keep all persons away from the 
discharge opening of hoses or  tools
or other points of compressed air
discharge. If the machine is 
installed in an enclosed area, be 
sure to vent the relief valve  outside
of the structure or to an unoccupied  area.
11.
DO NOT use air tools that are rated below the
maximum rating of the compressor. Select
air  tools,  air  hoses,  pipes,  valves,  filters  and 
other fittings accordingly. DO NOT  exceed 
manufacturer’s rated safe operating pressures 
for these items.
12.
Make sure all hose connections are adequate-
ly secured to prevent tools or hose ends from
being accidentally  disconnected.
Start-Up
1.
This  unit  is  shipped  with  pump  break-in  oil 
and should be ready to operate. Be sure to
check for  proper  oil  level  before operating 
the compressor. Oil  should be  in center of 
site glass. See figure  8.
Use only Airbase Industries oil 
(PN: APOL03000G1). Use of any
other product will cause product damage and void
the warranty.
2.
Check for proper belt tension. There should
be 1/2 inch slack. Refer to maintenance sec-
tion if adjustment is necessary.
Always make sure main power is
off before touching belts or other
moving parts of compressor.
3.
Lightly push power switch to make sure sys-
tem is  working.
4.
If motor shaft is not turning counter  clock-
wise, disconnect power to terminal block
then exchange any two of the three power
leads. Re-check  rotation.
Oil level should be to
center of red circle in
site  glass
Figure 8: Check proper oil level
To pump
unloaders
Open ball valve 
to engage 
continuous  run 
feature
Figure 9: Continuous run  feature
Continuous Run Feature 
(if equipped)
For heavy use applications such as sandblasting, the
continuous run feature is available. This feature keeps
main feed line open to eliminate numerous motor
starts/stops and to help cool pump.
To engage continuous run feature, open ball valve 
found by following copper tubing  across cylinder heads 
to tank. See figure  9.
Stop continuous run feature by closing valve so com- 
pressor will start and stop according to pressure   switch.
Maintenance
Safety Steps
Disconnect, tag and lock out  power
source then release all pressure from
the system before attempting to
install, service, relocate or perform
ANY maintenance.
1.
Make sure repairs are done in a clean, dry,  well
lighted and ventilated area.
2.
When cleaning, use air pressure less than  30 
psig (2.1bar). NEVER use flammable solvents 
for cleaning purposes. Also use effective chip
guarding and personal protective equipment
per OSHA standard 29 CFR 1910.242  (b).
3.
Relieve all internal pressure prior to  opening
any line, fitting, hose, valve, drain plug, con- 
nection or other component, such as filters and
line oilers, and before refilling optional air line 
anti-icer systems with antifreeze compound.
4.
Keep  electrical wiring, including  all  terminals 
and pressure connectors in good condition. Re-
place any wiring that has cracked, cut, or oth- 
erwise damaged insulation. Replace terminals 
that are worn, discolored or corroded. Keep all
terminals and pressure connectors clean and
tight.