VISUALIZATION AND SETTING OF THE PARAMETERS USER LEVEL
In the main menu, pushing the button the LCD visualizes the menu 0 “WORKING PRESSURE”; again by the button
flow other menu down and by the button flow them up; after the visualization of the last menu, the LCD shift
back to the main menu.
Once the menu has been selected, pushing the button enter into the programming or visualization of the pertinent
parameters.
ENTER THE PASSWORD
I
n the main menu, pushing the button and (both pushed), the LCD visualizes the message “PASSWORD N° 1-
2-3” with “1” blinking; by the button and/or select the password level and by the button confirm it: the
LCD visualizes the password level selected on the first row while “_ _ _ _ _ _” with the first under score blinking on the
second row; by the button and/or select the first number on the first under score and confirm it by the button
; set the next number according the same procedure and after confirmation of the last one the LCD visualizes the
first menu.
NOTE: for security reasons, just enter the figure are hidden
.
If the password entered is wrong the LCD visualizes the message “PASSWORD WRONG” for 5 seconds shifting back
to visualize the main menu.
Default values of the password levels:
Password service 1 = 22 (2 numbers)
Password service 2 = 4444 (4 numbers)
Password factory 3 = 666666 (6 numbers)
NOTE: quitting the setting under password, the password level selected is missed after 120 seconds since the last
pushing of any button.
PASSWORD MISSED?
In case you forget or miss the password number, to restore the default values, supply power to the controller keeping
the button pushed for 5 seconds; after this time the message “PRESET” blinks for 3 seconds to inform the default
value of the three password levels have been loaded again.
VISUALIZATION OF THE MENU
By the button and/or flow the menu up/do
wn; after the last menu the LCD shift back to the main
visualization.
Once the menu needed has been selected, by the button enter into visualization or programming of the pertinent
parameters.
VISUALIZATION AND SETTING OF THE PARAMETERS
By the button and/or select the paramet
er to change and confirm it by ; the data selected starts blinking;
by the button and/or change the data; pushing again confirm the new value and the data stops blinking;
visualizing the last parameter, pushing the button shift back to visualizes the menu selected.