Datasheet
SPEC No.
LCP-1109027
MODEL No.
LS013B4DN04
PAGE
19
6-5-5 COM Inversion
There are two types of inputs, COM signal serial input (EXTMODE=”L”) and external COM signal input (EXTMODE=”H”).
EXTMODE=“L”
SCS
SI
COM
M0 M1 M2 M0 M2M1 M2 M0 M1
fCOM
※2 ※2
※1 ※1 ※1
M1:LC polarity inversion flag: If M1is "H" then VCOM="H" is output. If M1 is "L" then VCOM="L" is output.
※1:LC inversion has been changed by M1 flag statement.
※2:The periods of plus polarity and minus polarity should be same length as much as possible.
EXTMODE=“H”
1) about the EXTCOMIN signal when SCS signal is H.
※1:LC inversion polarity has been set by the rising timing of EXTCOMIN in internal circuit block as COMZ signal,
※2:The period of EXTCOMIN should be constant.
2) about the EXTCOMIN signal when SCS signal is L.
※3:LC inversion polarity has been set by the rising timing of EXTCOMIN in internal circuit block as COMZ signal,
※4:The period of EXTCOMIN should be constant.