5.1 Contents of Reliability Tests
Item Conditions Criteria
High Temperature Operation
70°C, 240 hrs
Low Temperature Operation
-30°C, 240 hrs
High Temperature Storage
80°C, 240 hrs
Low Temperature Storage
-40°C, 240 hrs
High Temperature/Humidity Operation
60°C, 90% RH, 120 hrs
Thermal Shock
-40°C ⇔ 85°C, 24 cycles
60 mins dwell
The operational
functions work.
* The samples used for the above tests do not include polarizer.
* No moisture condensation is observed during tests.
5.2 Lifetime
End of lifetime is specified as 50% of initial brightness.
Parameter Min Max Unit Condition Notes
Operating Life Time
10,000
- hr 90 cd/m
2
, 50% Checkerboard 6
Storage Life Time
20,000
- hr
T
a
= 25°C, 50% RH
-
Note 6: The average operating lifetime at room temperature is estimated by the
accelerated operation at high temperature conditions.
5.3 Failure Check Standard
After the completion of the described reliability test, the samples were left at room
temperature for 2 hrs prior to conducting the failure test at 23±5°C; 55±15% RH.