6.1 Environment Required
Customer’s test & measurement are required to be conducted under the following
conditions:
Temperature: 23 ± 5°C
Humidity: 55 ± 15 %RH
Fluorescent Lamp: 30W
Distance between the Panel & Lamp: ≥ 50 cm
Distance between the Panel & Eyes of the Inspector: ≥ 30 cm
Finger glove (or finger cover) must be worn by the inspector.
Inspection table or jig must be anti-electrostatic.
6.2 Sampling Plan
Level II, Normal Inspection, Single Sampling, MIL-STD-105E
6.3 Criteria & Acceptable Quality Level
Partition AQL Definition
Major 0.65 Defects in Pattern Check (Display On)
Minor 1.0 Defects in Cosmetic Check (Display Off)
6.3.1 Cosmetic Check (Display Off) in Non-Active Area
Check Item
Classification
Criteria
Panel
General Chipping
Minor
X > 6 mm (Along with Edge)
Y > 1 mm (Perpendicular to edge)
X
Y
X
Y