Installation Guide

I n s t a l l a t i o n I n s t r u c t i o n s
Optional Electrical Junction Box
Wiring should be connected at a customer
provided junction box, outside the firebox.
Electrical Services
If an electrical supply of 120V is being roughed in
to the fireplace junction box to provide for future
installation of the optional blower kit, the wiring should
be connected to the internal J-Box (junction box) kit
(PROVIDED WITH THIS ACCESSORY).
NOTE: A FEW BASIC SAFETY RULES BEFORE
YOU START
1. All electrical connections (Figure 1) are to be made
in accordance with CSA Standard C22.1 Canadian
Electrical Code part 1 or with the National
Electrical Code, ANSI/NFPA 70 (latest edition)
and/or in accordance with local codes.
2. Make sure you have and are using/wearing proper
personal safety devices such as but not limited to
gloves, safety eye glasses/eye protection .
3. Check local building codes before installation of the
firebox and blower kit.
4. All wiring must be installed and/or inspected as
necessary to comply with the local authority
having jurisdiction.
Junction Box Wiring
1. Remove (2) J-Box retaining screws. (See Figure 3 )
2. Install J-Box Assembly into Fireplace
3. Attach household 110 VAC supply wire to
Receptacle.
4. Tighten Cable Clamp, install Receptacle and
Cover
6. Verify operation of outlet assembly in Fireplace
M
FIREBOX ENCLOSURE
INSTALLER:
WIRE INTERNAL RECEPTACLE
TO 110VAC HOUSE WIRING
PER APPLICABLE LOCAL CODES
BLOWER MOTOR ACCESSORY
SPST BLOWER SWITCH
STEEL HANDI-BOX
W/SINGLE GANG
RECEPTACLE
VFBC BLOWER WIRING DIAGRAM, ALL SIZES
Figure. 2
Figure 3
Figure 4
If installation of an accessory blower, or other “line-
Voltage” powered accessory may be desired,
you should install the J-Box accessory, and wiring
at the time of fireplace installation.
IT WILL NOT BE PRACTICAL TO INSTALL THIS
LATER!
3
Outlet and J-Box wil be positioned horizontally
in models VFBC32,A/B VFBC36A/B, and VFBC42A/B
(See Figure 4 )