Installation Guide

4
LIGHTING YOUR GAS LOGS WITH THE SAFETY PILOT KIT
1. Light Pilot
Turn Control Knob to Pilot Position (Figure 6 ), push knob fully in
and hold a long lighted match at the outlet of Pilot Burner Assembly.
After lighting the Pilot, hold the Control Knob in the ignition position
for approximately 45 seconds. This is an adequate time for the
Thermocouple to reach an operational temperature in order to
keep the Pilot lit once the Control Knob is released. If the Pilot
does not remain lit, turn the Control Knob to the Off position,
wait 5 minutes, then repeat the process as outlined above.
NOTE: If the Pilot continues to go out, check to be sure the Pilot
Thermocouple connection (Part #5) has not been overtight ened to
the Gas Control Valve.
2. Burner Ignition
To light the Burner, turn the Control Knob counter clockwise from the Pilot Position to the On Position
(See Figure 7). In this position, both the Pilot Burner and Main Pan Burner will be lit.
3. Burner Shutdown (Pilot remains lit)
To turn off the Burner Pan, move the Control Knob clockwise back to the Pilot Position (See Figure 6).
This will extinguish the Main Burner Pan, but will keep the Pilot Burner lit for instantaneous ignition of
the Main Burner Pan the next time you wish to use your gas log set.
4. Total Burner Shutdown (Burner and Pilot off)
To turn off the gas supply to the Main Burner Pan and the Pilot Burner move the Control Knob clockwise
from the Pilot Position to the "OFF" Position (See Figure 8).
NOTE: The Control Knob will need to be depressed slightly in order to move it from the Pilot Position to the
"OFF" Position.
Figure 6- Rotate control valve to Pilot
Position
Figure 7- Rotate control valve to On
Position to ignite burner
Figure 8- Rotate control valve to Off Pos-
ition for both Pilot and Burner shutdown
PILOT
ON OFF
Push Knob Fully
In to Light
Pilot